Construction Concerns: Pyrobar®

Middle

Article and photo by Gregory Havel

One of the first successful gypsum-based construction products, besides plaster, was Pyrobar®, manufactured by U. S. Gypsum (now a subsidiary of USG) beginning in 1903, and in regular use into the 1960s.

These gypsum blocks were larger than concrete blocks: usually 16 inches high by 32 inches long, whereas concrete blocks are 8 inches high and 16 inches long, including mortar joints. They were available in 4, 6, and 8-inch thicknesses, and were much lighter both because of the horizontal cores that they contained and the lighter weight of gypsum compared to concrete. They were designed to be laid up like a masonry wall with mortar, and the surfaces on both sides were ready to be finished with plaster.

The gypsum material does not have enough strength for use as load-bearing walls. It was common for a building with a steel frame to have its interior partitions built of Pyrobar® and plaster, and for the steel columns and beams to be enclosed with the same material for fire resistance. This was common in schools, commercial buildings, hospitals, and apartment buildings.

The photo below was taken in 2004, during the renovation of a mansion built in southeastern Wisconsin around 1950. It shows both four and six-inch Pyrobar®, with part of the enclosure of the steel column removed, and an electrical conduit running horizontally through a core in the gypsum block.

Since gypsum is calcium sulfate with water bound up in its molecules (the chemical formula for hydrous calcium sulfate is CaSO4-2H2O), it is naturally fire-resistive and noncombustible. It takes a lot of heat to drive the water out of gypsum. Walls of plastered Pyrobar® with one and two-hour fire ratings were common, and the material could be used to achieve three and four-hour fire ratings.

There are still many buildings that were built using this material, even though it has not been manufactured for more than 40 years. While the gypsum block was never manufactured using asbestos, a known carcinogen, the mortar with which it was laid often contained significant amounts--an argument in favor of gross decontamination of firefighters after interior firefighting or overhaul, before we remove our SCBA and other personal protective equipment.

Gregory Havel is a member of the Town of Burlington (WI) Fire Department; retired deputy chief and training officer; and a 30-year veteran of the fire service. He is a Wisconsin-certified fire instructor II and fire officer II, an adjunct instructor in fire service programs at Gateway Technical College, and safety director for Scherrer Construction Co., Inc. Havel has a bachelor's degree from St. Norbert College and has more than 30 years of experience in facilities management and building construction.

August 12, 2007

Fire Engineering Blog

Left

Our advisory board discusses hot topics in the fire service. Your comments welcome!

Most recent blog topics:
Please wait while the feed is being loaded...

QUICK VOTE

Do you train with industrial fire brigades in your area?
Yes
No
Your vote will only be recorded once


Top

Corbett's Trivia

Corbett's Trivia
What was the name of the shrieking whistle device attached to a fire engine's exhaust that was used to clear the path of vehicles and pedestrians?
More Corbett's Trivia
Middle1

FIREFIGHTER FATALITIES

Steve D. Kline of the Stone Park Fire Department in Stone Park, IL has died as the result of an on-duty incident that occurred on 2008-11-18.
More Firefighter Fatalities More
Right1
Right2
Right
Right3
Bottom1
Bottom2
Bottom3