Arkansas Crew Saves Man After Gas Detection

A Springdale (AK) crew received a 911 call for an unconscious/unresponsive male at a local poultry production plant. They sent a typical response of an engine and a medic unit.

They arrived on scene and found a male patient down and unresponsive and started to treat the call like a typical cardiac event. They hooked the monitor to the patient and realized that his SPCO2 was over 40.

Due to the training they had been provided on the subject of CO and HCN exposure, they recognized this may be one of those cases. They placed the patient on the cot and moved him to the squad. Still following ALS protocols for a cardiac incident, the patient was placed on high flow O2 and baseline vitals were obtained.

The patient started to come around and stated he had a taste of sour almonds in his mouth. This of course is another sign of possible HCN poisoning and the captain picked up on it. The engine captain sent his firefighter to the engine to get the 4 gas meter and zero it out.

Their meters on the engine companies are equipped with O2, LEL, CO and HCN. The medic crew initiated transport and the firefighter returned with the meter. They found no indications of any problems in the immediate area. They entered the boiler room where the patient was said to working and immediately the meter started alarming. The CO was 383 ppm and the HCN was 65ppm. The engine captain again recognized this information needed to be passed along to the medic crew and remembered that HCN’s IDLH is 50 ppm. He called them on the radio and advised this was a HCN incident. The engine captain had the building evacuated and the maintenance personnel turned on the vent fans. The toxic environment was ventilated quickly and the plant personnel were able to enter the boiler room to find the problem and fix it.

The medic crew, based on the meter reading and the signs and symptoms of the patient, advised the ER doctor of their findings. The medic advised the doctor that the patient needed the Cyanokit. The doctor wanted to verify the information so he asked the medic a few quick questions, one of which was: What was going to happen if he administered the kit?

The doctor agreed that the kit was warranted due to the signs and symptoms, but most importantly due to the meter readings. It is imperative that crews recognize the signs and symptoms, but it is more important that they can back it up with real numbers from meters. Doctors across the nation don’t always recognize HCN exposure because it is and can be confused with CO poisoning.

David Rhodes

The Search Is Still On!

Your fire department should find the right strategy and tactics to accomplish search in the first few minutes after arrival.